WebLogic Error: more than the configured time (StuckThreadMaxTime) of “600” seconds

I came into the below error in Oracle BI Publisher when ran a  report that takes more time to produce output  

 

BI Publisher Error in the WebLogic Server Log 

The highlighted red color text indicates the root cause of the error. 

 

<Jun 13, 2017 11:14:08 AM EDT> <Error> <WebLogicServer> <HOSTNAME> <bi_server1> <[ACTIVE] ExecuteThread: ‘8’ for queue: ‘weblogic.kernel.Default (self-tuning)’> <<WLS Kernel>> <BEA-000337> <[STUCK] ExecuteThread: ‘4’ for queue: ‘weblogic.kernel.Default (self-tuning)’ has been busy for “669” seconds working on the request “Workmanager: default, Version: 0, Scheduled=true, Started=true, Started time: 669272 ms

[POST /xmlpserver/viewer/runstatus.jsp?_xdo=%2FP6Reports%2FReports%2Myreport.xdo HTTP/1.1
Accept: */*
If-Modified-Since: Sat, 1 Jan 2000 00:00:00 GMT
Content-Type: application/x-www-form-urlencoded
Referer: https://localhost:8203/xmlpserver/P6Reports/Reports/Component/Myreport.xdo
Accept-Language: en-US
Accept-Encoding: gzip, deflate
User-Agent: Mozilla/5.0 (Windows NT 6.1; WOW64; Trident/7.0; rv:11.0) like Gecko
Content-Length: 0
Connection: Keep-Alive
Cache-Control: no-cache]”,

 

which is more than the configured time (StuckThreadMaxTime) of “600” seconds. Stack trace: null>

 

Solution: 

 

Adjust the following settings to Admin and Managed servers in WebLogic server

 

  Default Value Suggested Value
Admin and Managed Server Stuck Thread Max Time=600
Stuck Thread Timer Interval=60
Max Stuck Thread Time=600
Stuck Thread Max Time=2400
Stuck Thread Timer Interval=2400
Max Stuck Thread Time=2400

 

how to Set this value: 

 

  • Log in to WebLogic console 

 

  • Click on the Admin server >> Click on the Configuration tab >> Tuning tab and set the below values 

 

 

 

  • Click on the OverLoad tab and set the below value 

 

 

  • Report the steps and apply to all  managed servers 
govindan WebLogic Error:  more than the configured time (StuckThreadMaxTime) of "600" seconds
Connect me

Govind

Thank you for visiting my personal blog. Myself Govindan, Software Developer by profession since 2006 and hence I started this blog early in 2016 and ever since I've been writing about technologies experienced and learnings of everyday life.

The views expressed on this blog are my personal views and do not necessarily reflect the views of my employer.

Please feeling free to reach me on any comments and feedbacks you have. Would be more than glad to listen and reply 🙂
govindan WebLogic Error:  more than the configured time (StuckThreadMaxTime) of "600" seconds
Connect me
By | 2017-06-13T13:00:01+00:00 June 13th, 2017|Categories: BI, WebLogic|Tags: |0 Comments
Like us on Facebook.
Connect!